Siemens generator circuit breaker
Realistically, most enclosures were around 104° F a common special breaker was used for these types of situations. For many years, all breakers were calibrated for 77° F which meant that all breakers above this temperature had to be derated.
#Siemens generator circuit breaker code#
Ampere rating is governed by the National Electrical Code (NEC) and is the primary source for information about load cycles in the electrical contracting industry. A general rule of thumb for circuit breaker manufactures is to calibrate their standard breakers at 104° F.Īmpere rating for any standard application depends solely on the type of load and duty cycle. This ampere rating is the continuous current the breaker will carry in the ambient temperature where it was calibrated. In regards to continuous current rating, molded case circuit breakers are rated in amperes at a specific ambient temperature. Failure to apply the correct amount of interrupting capacity will result in damage to the breaker. The one infallible rule that must be followed when applying the correct circuit breaker is that the interrupting capacity of the breaker must be equal or greater than the amount of fault current that can be delivered at the point in the system where the breaker is applied. Determining the maximum amount of fault current supplied by a system can be calculated at any given time. The interrupting rating is generally accepted as the highest amount of fault current the breaker can interrupt without causing system failure to itself. It is best to check ahead of time with an electrical contractor to make sure calibration measures are in place before moving forward with a 50 Hz project.
#Siemens generator circuit breaker generator#
If doing a diesel generator project the frequency will either be 50 Hz or 60 Hz.
Solid state trip breakers are pre-calibrated for 50 Hz or 60 Hz applications. For 50 Hz AC minimum applications special calibration is generally available. A general rule of thumb is the higher the ampere rating in a specific frame size the greater the derating needed.Īll higher rated breakers over 600 amps contain a transformer-heated bimetal and are suitable for 60 Hz AC maximum. The total quantity of deration depends on the ampere rating, frame size as well as the current frequency. During higher frequency projects, the eddy currents and iron losses causes greater heating within the thermal trip components thus requiring the breaker to be derated or specifically calibrated. Higher than 120 Hz frequencies will end up with the breaker having to derate.
It is important to select a circuit breaker with enough voltage capacity to meet the end application.Ĭircuit breakers up to 600 amps can be applied to frequencies of 50-120 Hz. The overall voltage rating is calculated by the highest voltage that can be applied across all end ports, the distribution type and how the circuit breaker is directly integrated into the system. This article will give a step by step overview on selecting an appropriate circuit breaker for your specific application. There are a few different criteria to consider when selecting a circuit breaker including voltage, frequency, interrupting capacity, continuous current rating, unusual operating conditions and product testing.